Two types of fans are available for AT4 air-conditioners: the radial fan or the AL-KO AIR-vent - the impeller-type fan.



 


Direct-reading pressure gauge
Indicator to measure the differential pressure on the closed
circular tubing.

double-entry air intake and spiral housing
three-phase motor type B, motor fully protected by PTC resistor
motor clamp slide
belt drive, V-belt pulleys with taperlock spring collet system
flexible packing between fan outlet and chamber by means of airtight canvas nozzle
equipotential bonding between motor unit of the fan and unit housing.
entire drive unit supported by compressed spring-type shock absorbers
fan unit can be removed at the side of the air-conditioning system
safety locking for transport
performance data of the fan documented by TÜV certified characteristisic
performance curve, max. deviation +/- 5%.
 

Various models:
Fan with forward-curved blades
Fan with backward-curved blades
Fan with backward-curved blades, reinforced housing and bearings
   
Available accessories:
Grille
Closed circular tubing
Direct reading pressure gauge
Frequency transformer


 

The Air-vent is a radial fan with single-entry air intake and backward curved blades. The entire drive unit is supported by compressed
spring-type shock absorbers and allows adjustment of the nozzle gap for exact adjustment of the setpoint. The three-phase A.C. motor corresponds to type B, thus ensuring full motor protection by means of a PTC resistor.

The impeller is placed directly on the motor shaft (taper lock spring collet). The fan unit can be removed at the side of the air-conditioner and is equipped with a transport safety locking device. The fan's performance data are documented by a TÜV-certified performance curve (max. design deviation +/- 5%)

Available accessories
Closed circular tubing, direct reading pressure gauge, frequency transformer and grille (see picture) are available as accessories. The latter consists of zinc-coated steel sheets with punched in oblong perforations to provide an unobstructed view of the fan unit. Design in conformance with accident prevention regulations (UVV).

For more details on the AIR-vent, the fan with radial impeller, and its functioning go to the Quality and safety category.





E-mail, address, how to reach us

  Self-contained air-conditioning systems
Base AT 4 air-conditioning systems
Systems for use in clinics
Weatherproof systems
Integrated refrigeration
  Standard systems
Flat units AT 2
  Commercial systems
Commercial AT 58 systems
  Air Heater
AK Warm Air Heater
Komfort Air Heater
Energie Air Heater
Industrie Air Heater
SL-KH Cooler/Heater
   
Control systems
Quality & safety

  Functional units
Filters
Coolers & heaters
Sound absorbers
Fans
Heat recovery
Housing
Accessories
Technical data

Our General Terms of Supply contain important information for you.